Analisis Sistem Instalasi Kelistrikan pada Swiss-Belhotel Makassar dengan Menggunakan Program ETAP

Authors

  • Ishak Amar Politeknik batulicin
  • Imam Ridwan Tanaka Politeknik Batulicin
  • Riyki Apriandi Politeknik Batulicin
  • Usman Haya Politeknik Batulicin

DOI:

https://doi.org/10.36499/jim.v21i1.13294

Keywords:

Electrical evaluation, Swiss-Belhotel Makassar, ETAP, electric power system, load analysis

Abstract

Swiss-Belhotel Makassar as a five-star hotel requires a reliable electrical installation system to support operations and customer comfort. Electrical system evaluation is important to ensure that system performance remains optimal, safe, and meets standards. This study aims to analyze and evaluate the existing condition of the electrical installation at Swiss-Belhotel Makassar using the Electrical Transient Analyzer Program (ETAP) software. The methods used include primary and secondary data collection, single line diagram system modeling, and short circuit current simulation and load analysis. The evaluation results show that there are several system components that are approaching their maximum capacity limits, as well as load imbalances between phases that need to be corrected to avoid potential disruptions and low energy efficiency. By using ETAP simulation, technical recommendations are prepared such as protection adjustments, load balancing, and system configuration improvements. This evaluation provides an important overview in efforts to improve the reliability and safety of the hotel's electrical system as a whole.

 

References

B. Udara, I. G. Ngurah, R. Bali, I. W. Sutama, and D. Candra, (2023) “Analisis Perbaikan Faktor Daya Pada Tranformator 2500KVA / 400V di,” vol. 6.

M. Arriski, (2020). Anal. efisiensi Mot. induksi 380V 3 phasa Pada PHOSTHATE FEDD PUM di PT. Pertamina III.

M. Digo, U. Situmeang, and Z. Elvira, (2022). “Analisis Kinerja Motor Induksi 3 Phasa Pada Screw Press,” J. Sain, Energi, Teknol. Ind., vol. 6, no. 2.

Pardamean Sinurat, dkk (2017). “Analisis Karakteristik Sistem Tenaga Listrik Saat Manuver Dengan Simulasielectrical Transient Analysis Program (ETAP)”, Jurusan Teknik Elektro, Fakultas Teknologi Industri Institut Teknologi Medan.

Sylvia Oktobella, Bambang Anggoro, Waluyo. (2015). Studi Karakteristik Nilai Impedansi Riil dan Imajiner Impedansi Pentanahan Konfigurasi Vertikal dengan Variasi Diameter dan Diinjeksi Arus Bolak-Balik Berfrekuensi 50 Hz -2 MHz. Jurnal Online Institut Teknologi Nasional. Vol.3 No.3.

Samsurizal, Muhammad Awaluddin, Septianisa Azzahra, Nurmiati Pasra, Andi Makkulau. 2024. Pemantauan dan Kontrol Otomatis Efisiensi Sel Surya melalui Simulasi Solar Tracker dengan Mikrokontroler. Fakultas Ketenagalistrikan dan Energi Terbarukan, Institut Teknologi PLN Jakarta, Vol. 18. No. 03.

Direktorat Jenderal Ketenagalistrikan. (2000). Persyaratan Umum Instalasi Listrik (PUIL 2000). Jakarta: Departemen Energi dan Sumber Daya Mineral Republik Indonesia.

Prih Sumardjati, dkk., (2020) Teknik Pemanfaatan Tenaga Listrik Jilid 3 Hal. 408. Vol. 6.

Imron Ridzki, dkk., (2022). “Analisisperbandingan tipe belitan terhadap nilai parameter motor induksi satu fasa”. Jurusan Teknik Elektro, PoliteknikNegeri Malang, Indonesia., Vol.20, no.1

Published

2025-04-30

How to Cite

Amar, I., Tanaka, I. R., Apriandi, R., & Haya, U. (2025). Analisis Sistem Instalasi Kelistrikan pada Swiss-Belhotel Makassar dengan Menggunakan Program ETAP. Majalah Ilmiah Momentum, 21(1), 67–77. https://doi.org/10.36499/jim.v21i1.13294

Issue

Section

Articles